Film Badges
A special film is used which is coated with two different emulsions. One side is coated with a large grain, fast emulsion that is sensitive to low levels of exposure. The other side of the film is coated with a fine grain, slow emulsion that is less sensitive to exposure. If the radiation exposure causes the fast emulsion in the processed film to be darkened to a degree that it cannot be interpreted, the fast emulsion is removed and the dose is computed using the slow emulsion.
The major advantages of a film badge as a personnel monitoring device are that it provides a permanent record, it is able to distinguish between different energies of photons, and it can measure doses due to different types of radiation. It is quite accurate for exposures greater than 100 millirem. The major disadvantages are that it must be developed and read by a processor (which is time consuming), prolonged heat exposure can affect the film, and exposures of less than 20 millirem of gamma radiation cannot be accurately measured.
Film badges need to be worn correctly so that the dose they receive accurately represents the dose the wearer receives. Whole body badges are worn on the body between the neck and the waist, often on the belt or a shirt pocket. The clip-on badge is worn most often when performing X-ray or gamma radiography. The film badge may also be worn when working around a low curie source. Ring badges are worn on a finger of the hand most likely to be exposed to ionizing radiation. A LIXI system with its culminated and directional beam would be one example where monitoring the hands would be more important than the whole body.